M328 measurable inductance capacitance ESR table for measuring instrument

M328 measurable inductance capacitance ESR table for measuring instrument

Availability: In stock

$21.15

Guaranteed genuine products from DIY3DP

Don't forget to checkout with DIY3DP Discount codes

Discount System
1

order $50+ receive 3% off -- use coupon DIY3DP03OFF50

2

order $100+ receive 5% off -- use coupon DIY3DP05OFF100

3

order $200+ receive 8% off -- use coupon DIY3DP08OFF200

4

order $300+ receive 12% off -- use coupon DIY3DP12OFF300

5

order $500+ receive 15% off -- use coupon DIY3DP15OFF500

Details

Details

M328 measurable inductance capacitance ESR table for measuring instrument Specifications: Resistor:0.5 Ω-50MΩ Capacitor:30pF-100mF Inductance:0.01MH-10H Working voltage: can use 6FF22 9V Battery, or DC 5.5-12V via DC socket. Controller :ATmega168 Standby current:0.02uA Operating current: 25mA Features: * Automatic detection PNP and NPN type bipolar transistors , N, P -channel MOSFET, JFET FET , diodes , two diodes, thyristors , resistors , capacitors , inductors . Automatic detection pin definitions. * Measurement of the bipolar transistor current amplification factor (B) and conduction voltage emitter junction (Uf). Darlington transistor may be identified by the amplification factor of the high threshold voltage and high current . * The threshold voltage and the MOSFET gate capacitance measurement . * Support two measuring resistors , the potential can also be measured . If the potentiometer is adjusted to its end , the tester can not distinguish the two ends of the pin and the middle . * Resistance measurement resolution is 0.1 ohm , the highest measurement value of 50M ohms * capacitance measurement range from 25pf to 100mF (10UF). Resolution up to 1 PF. can detect more than 2UF capacitor equivalent series resistance (ESR), with a resolution of 0.01 ohms. This feature is very important for the detection capacitor performance. * You can display symbols of the two diodes in the right direction , also shows the forward voltage drop . * LED detection of diode forward voltage drop higher than normal . Dual LED detected as double diodes. Simultaneous detection of light-emitting diodes will flash . each test time is about two seconds , only large capacitance and inductance measurements will take a long time .

Tags

Tags

Use spaces to separate tags. Use single quotes (') for phrases.

Special Requirements

SPECIAL REQUIREMENTS

In case you need very special requirements: we recommend to contact us before purchasing

Write Your Own Review

Only registered users can write reviews. Please, log in or register